Vacuum camerae TJC20-7.2/400
Vacuum cameraTJC20-7.2/400
Parameter
Nec. | MAIN ARTI DATA | Unitas |
| |
1 | Rated Voltage | kV | 7.2 | |
2 | Fulmen impetus sustinere intentione (Peak) | kV | 60 | |
3 | Brevi tempore (1min) Power-frequency resistere intentione | kV | 32 | |
4 | Rated Frequency | Hz | 50/60 | |
5 | Ratum Current | A | 400 | |
6 | Rated breve tempus sustine Current | kA | 4 | |
7 | Rated spatium breve spatium | s | 4 | |
8 | Rated Breaking Current | A | 4000 | |
9 | Limiting Breaking Current | kA |
| |
10 | Rated Condita Current | kA | 10 | |
11 | Rated Operating Frequency | AC-3 | Res / h * |
|
AC-4 | 300 | |||
12 | Brevi tempore Operating Frequency | Res / h * |
| |
13 | Utendo Categoria | AC |
| |
14 | Patientia electrica | AC-3 | Operationes | 2.5*105 |
AC-4 | 10*104 | |||
15 | Mechanica patientia | Operationes |
| |
16 | Clearance inter Open Contactus | mm | 4 ~ 5.5 | |
17 | Contactus claudunt Ob folles et atmosphaerae | N | 70+ -10 | |
18 | Contra vim Contactum in plena Stroke | N | 90+ -10 | |
19 | Ambitus Resistentia ad Min.Ratum Contact Force | μΩ | <= 160 | |
20 | Contact Low Erosion | mm | 1.5 | |
21 | Missa de Movendis Partibus | kg | 0.42 | |
22 | Internum Gas Pressura | Pa | <=1.33*10-3 | |
23 | Fasciae vita | Annus | 20 |