JCZR Combination of Vacuum Contactor and Fuse

Short Description:

JCZR Combination of Vacuum Contactor and Fuse JCZR(ZFCC5) serial is a combination of AC High Voltage Vacuum Contactor and Fuse. It features for the industrial control system that frequency: 50Hz, rated voltage: 12kV(7.2kV), rated current: 225A(Max.)(for 7.2kV: 315A Max.). It can be matched with switch-gear to built F-C circuit, be used together with general protection. It can control and protect high voltage motor, transformer and capacitor bank. Products design: 1. JCZR is a F-C combination...


  • FOB Price: US $0.5 - 9,999 / Piece
  • Min.Order Quantity: 1 Piece/Pieces
  • Supply Ability: 200 Piece/Pieces per Month
  • Port: Shanghai
  • Payment Terms: T/T
  • Product Detail

    Product Tags

    JCZR Combination of Vacuum Contactor and Fuse

    JCZR(ZFCC5) serial is a combination of AC High Voltage Vacuum Contactor and Fuse. It features for the industrial control system that frequency: 50Hz, rated voltage: 12kV(7.2kV), rated current: 225A(Max.)(for 7.2kV: 315A Max.). It can be matched with switch-gear to built F-C circuit, be used together with general protection. It can control and protect high voltage motor, transformer and capacitor bank.

    Products design:
    1. JCZR is a F-C combination of JCZ5 Vacuum Contactor and High Voltage Current Limiting Fuse by series. The control function is realized by JCZ5 Vacuum Contactor and the protection function is realized by High Voltage Current Limiting Fuse.
    2. JCZR use VSI(ZN63A) breaker base cart as the swing bar structure. It has the compact structure, and its dimension is matched with KYN28 high voltage gear.

     

    “Eight Protection” use the reliable lock structure, can be avoided the below mentioned electrical wrong operation:

    1.  When the contactor is opened, the cart can be moved;

    2.  When the cart is in break/test position and operation position, the contactor can be closed;

    3.  When the earthing switch is in opening position, the cart can be moved from test position to operation position;

    4.  When the cart is in any position between operation and test, the earthing switch can not be closed;

    5.  When the cart is only in break/test position, the earthing switch can be closed;

    6.  When the cart is only in break/test position, the door of the cart can be opened;

    7.  When the cart is in operation position, the secondary plug will be locked and not to be pulled out;

    8.  The contactor is in the close position, whenever the cart is in the operation or test position, the cart can not be moved.

    Parameters

    Rated Voltage

    7.2kV

    12kV

    Rated current

    According to fuse 315A Max.

    According to fuse 225A Max.

    Rated frequency

    50Hz

    50Hz

    Rated short circuit turn-on current

    4000A

    4000A

    Rated interrupted current

    100000A

    100000A

    AC current

    3150A

    3150A

    1 minute Industrial frequency Bearing Current

    32kA

    42kA

    Thunder Shock Bearing Voltage

    60kV

    75kV

    Switch On & Off Condenser's Current

    230A

    230A

    Fuse

    XRNM-7.2kV XRNT-7.2kV

    XRNM-12kV XRNT-12kV

    Max. Load be controlled

    Motor

    2.4kW

    2.8kV

    Transformer

    3150kVA

    2250kVA

    Weight

    85kgs

    108kgs