CKG4 high-voltage vacuum contactor

Short Description:

CKG4 high-voltage vacuum contactor CKG4 series high-voltage vacuum contactor consist of separable insulator bracket and metal frame. It has advantage of firm structure, high reliability, contact from the large open, better breaking capacity and smaller bounce at contact closing and opening. It is suitable for the distribution system of metallurgy, mine, petrol-chemistry and building, to control the equipment used electricity such as high-voltage motor of 12kV or under 12kV, transformer and ca...


  • FOB Price: US $0.5 - 9,999 / Piece
  • Min.Order Quantity: 1 Piece/Pieces
  • Supply Ability: 200 Piece/Pieces per Month
  • Port: Shanghai
  • Payment Terms: T/T
  • Product Detail

    Product Tags

    CKG4 high-voltage vacuum contactor

    CKG4 series high-voltage vacuum contactor consist of separable insulator bracket and metal frame. It has advantage of firm structure, high reliability, contact from the large open, better breaking capacity and smaller bounce at contact closing and opening. It is suitable for the distribution system of metallurgy, mine, petrol-chemistry and building, to control the equipment used electricity such as high-voltage motor of 12kV or under 12kV, transformer and capacitor loading etc. Especially suitable for frequent operation domain. Because of its small volume, light weight and packaged design of upper and lower arrangement, prevalent in the world. It is convenient to use and maintain, and is easy to form the complete equipment of F-C loop.

    Electric parameter

    Main circuit rated voltage (kV)

    12/7.2

    Main circuit rated current (A)

    800,  630,  400,  200

    Main circuit making capacity (A/100times)

    6300, 6300, 4000, 2000

    Main circuit breaking capacity (A/25times)

    5040, 5040, 3200, 1600

    Limit breaking capacity(A/3times)

    6300, 6300, 4000, 2000

    Mechanical life (time)

    100 x 104

    Electric life AC3 (time)

    25 x 104

    Electric life AC4 (time)

    10 x 104

    Rated operating frequency (time/h)

    300

    Main circuit power frequency withstand voltage (gap) (kV)

    42

    Phase to Phase, Phase to earth power frequency withstand voltage (kV)

    42

    Lightning impulse withstand voltage (kV)

    75

    Main circuit contact resistance (μΩ)

    ≤200

    Clearance between open contacts (mm)

    6±1

    Overtravel (mm)

    1.5±0.5

    Secondary control voltage (V)

    AC:110 /220  DC:110/220

    Secondary control current (A)

    DC:14A/7A (800、630A)

    DC:6A/3.5A (400A、200A)